The Nature of Steam If we carry out the same procedure at altitude (e.g.) boiling water for coffee whilst on a hiking trip in the mountains, we find that although the water still boils the coffee does not stay hot for as long as it does at sea level. This is because the boiling point of water is affected by pressure. In this application note we will refer to pressure in units of pounds per square inch absolute (psia). As the pressure decreases the boiling point of water decreases, as the pressure increases the boiling point of water increases. Some examples will illustrate this point.
The natural boiling point of water at any give pressure is known as the saturation temperature. Steam produced at these conditions is known as saturated steam. If the steam is heated above its saturation temperature it is known as superheated steam. The number of degrees above the aturation temperature that the steam is heated to is known as the number of degrees of superheat. (e.g.) 100 psia steam heated to 428ºF would possess 100 degrees of superheat. Water, in all its forms, is one of the best documented fluids. The properties of steam are fully documented in steam tables, the above information on boiling points is derived from this source.
Enthalpy and Density From the steam tables it is seen that the density of steam is completely defined by its temperature and pressure. Therefore by making a continuous measurement of temperature and pressure in a steam line we can calculate the density of the steam on a continuous basis. If we simultaneously make a measurement of the volumetric flow of the steam we can calculate the mass flow of the flow stream. This is done by multiplying the volumetric flow by the density.
Buying Steam or Accounting for its Use
Steam Mass Flow Versus Volumetric Flow The customer will be paying the same amount for less energy. By measuring pressure, temperature and flow and using a MASStrol to perform the mass calculation and compensation function any change in the properties of the flow stream will be detected. The customer is therefore billed only for the energy that is used.
Causes of Temperature and Pressure Loss
What Errors can be Caused by Measuring on a Volumetric Basis The diagram overleaf gives an indication of typical errors that can be caused by measuring on a volumetric basis.
As can be seen there is no error in the mass figures (20000 lb/hr into and out of the steam network), but the volumetric figures show a 9% error (67340 ft³/hr into the network but 77367 ft³/hr going out) The errors calculated here are conservative, actual figures on a plant are usually much worse.
|